Three-port device S-parameter characterization by means of an original three-port test set

Ferrero, A. ; Pisani, Umberto (1992) Three-port device S-parameter characterization by means of an original three-port test set. In: Gallium Arsenide Applications Symposium. GAAS 1992, 27-29 April 1992, Noordwijk, The Netherlands.
Full text available as:
[thumbnail of GAAS_92_073.pdf]
Preview
PDF
Download (1MB) | Preview

Abstract

A three-port network analyzer, implemented using commercial available hardware is presented, Test set calibration is accomplished through a particular calibration procedure which requires only conventional standards, used for two-port applications, and minimizes the number of their connections. Experimental verification was carried out through measurement of a directional cou­pler and several devices with one and two ports.