Raw experimental data for: "Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsampling" — MRM parameters, extraction solvent screening, extraction yield, matrix effect, calibration, precision and accuracy, hematocrit independence, stability, dilution integrity, selectivity and carryover, and application to authentic whole blood specimens

Protti, Michele ; Mercolini, Laura ; Mandrioli, Roberto (2026) Raw experimental data for: "Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsampling" — MRM parameters, extraction solvent screening, extraction yield, matrix effect, calibration, precision and accuracy, hematocrit independence, stability, dilution integrity, selectivity and carryover, and application to authentic whole blood specimens. University of Bologna. DOI 10.6092/unibo/amsacta/9093. [Dataset]

This is the most updated version of the document.

Full text available as:
[thumbnail of Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsampling" — MRM parameters, extraction solvent screening, extraction yield, matrix effect, calibration, precision and accuracy, hematocrit independenc] Spreadsheet (Non-psychotropic phytocannabinoids, Δ9-THC and their metabolites by means of volumetric dried blood microsampling" — MRM parameters, extraction solvent screening, extraction yield, matrix effect, calibration, precision and accuracy, hematocrit independenc)
License: Creative Commons: Attribution 4.0 (CC BY 4.0)

Download (202kB)
[thumbnail of README file] Text(docx) (README file)
License: Creative Commons: Attribution 4.0 (CC BY 4.0)

Download (19kB)

Abstract

This dataset provides the raw and derived data underlying the full method development and validation of the HPLC-MS/MS multi-cannabinoid method described in the associated manuscript: MRM parameters, extraction-solvent screening, final-method extraction yield and matrix effect, calibration curves, precision and accuracy, hematocrit independence, stability, dilution integrity, selectivity and carryover, and the application to authentic whole blood specimens with cross-matrix comparison against an SPE plasma-based reference method. Derived parameters (EY%, ME%, IS-ME%, %RSD, accuracy, bias, % deviation) are included per row to allow independent verification of the reported validation outcomes.

Abstract
Document type
Dataset
Creators
CreatorsORCIDAffiliationROR
Protti, Michele0000-0001-9310-4957Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna01111rn36
Mercolini, Laura0000-0002-0644-9461Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna01111rn36
Mandrioli, Roberto0000-0001-9631-591XResearch Group of Advanced Pharmaceutical Analysis (APA Lab), Department for Life Quality Studies (QuVi), Alma Mater Studiorum – University of Bologna01111rn36
Keywords
non-psychotropic cannabinoids; Δ9-tetrahydrocannabinol; cannabidiol; metabolites; HPLC-MS/MS; volumetric blood microsampling; capillary-generated dried blood spot (cDBS); bioanalytical method validation
Subjects
DOI
Contributors
Name
ORCID
Type
Affiliation
ROR
Protti, Michele
Contact person
Research Group of Pharmaco-Toxicological Analysis (PTA Lab), Department of Pharmacy and Biotechnology (FaBiT), Alma Mater Studiorum - University of Bologna
Deposit date
31 Jul 2026 13:07
Last modified
31 Jul 2026 13:07
Project name
ESILARANTE - ElectroSpray Immobilization of LAccase foR cANnabinoids deTEction
Funding program
Italian Ministry of University and Research - National Recovery and Resilience Plan (PNRR), Mission 4, Component 2, Investment 1.1 – PRIN 2022 funding program
URI

Other metadata

Available versions of this document

Downloads

Downloads

Staff only: View the document

^