Data about the determination of lithium-ion diffusion coefficient in graphite electrodes

Gregucci, Alessandro ; Staffolani, Antunes ; Soavi, Francesca (2026) Data about the determination of lithium-ion diffusion coefficient in graphite electrodes. University of Bologna. [Dataset]
Full text disponibile come:
[thumbnail of READ ME FILE] Documento di testo(docx) (READ ME FILE)
Licenza: Creative Commons: Attribuzione 4.0(CC BY 4.0)

Download (22kB)
[thumbnail of Independent from area diffusion coefficient calculated from both Galvanostatic Intermittent Ti-tration Technique (GITT) and Intermittent Current Interruption (ICI), during lithiation and delithia-tion, as well as the Open Circuit Voltage (OCV) curve a] Foglio di Calcolo (Independent from area diffusion coefficient calculated from both Galvanostatic Intermittent Ti-tration Technique (GITT) and Intermittent Current Interruption (ICI), during lithiation and delithia-tion, as well as the Open Circuit Voltage (OCV) curve a)
Licenza: Creative Commons: Attribuzione 4.0(CC BY 4.0)

Download (13kB)
[thumbnail of diffusion coefficients calculated from Intermittent Current Interruption (ICI), by using the GA area, the Scanning Electron Microscope (SEM) area and the Brunauer–Emmett–Teller (BET) area, during lithiation and delithiation, as well as the Open Circuit Vo] Foglio di Calcolo (diffusion coefficients calculated from Intermittent Current Interruption (ICI), by using the GA area, the Scanning Electron Microscope (SEM) area and the Brunauer–Emmett–Teller (BET) area, during lithiation and delithiation, as well as the Open Circuit Vo)
Licenza: Creative Commons: Attribuzione 4.0(CC BY 4.0)

Download (14kB)
[thumbnail of potential profile of the Galvanostatic Intermittent Titration Technique (GITT), as well as the two examples fit data] Foglio di Calcolo (potential profile of the Galvanostatic Intermittent Titration Technique (GITT), as well as the two examples fit data)
Licenza: Creative Commons: Attribuzione 4.0(CC BY 4.0)

Download (399kB)
[thumbnail of Mean value of the particle sizes] Foglio di Calcolo (Mean value of the particle sizes)
Licenza: Creative Commons: Attribuzione 4.0(CC BY 4.0)

Download (9kB)

Abstract

Here the raw electrochemical data related to the evaluation of the impact of the electrode area estimation on the lithium-ion diffusion coefficients in graphite electrode are reported.

Abstract
Tipologia del documento
Dataset
Autori
AutoreORCIDAffiliazioneROR
Gregucci, Alessandro0009-0009-7903-824XUniversity of Bologna01111rn36
Staffolani, Antunes0000-0002-1144-0074University of Bologna01111rn36
Soavi, Francesca0000-0003-3415-6938University of Bologna01111rn36
Parole chiave
Lithium Ion Diffusion, Graphite
Settori scientifico-disciplinari
Contributors
Contributor
ORCID
Tipo
Affiliazione
ROR
Soavi, Francesca
Contact person
University of Bologna
Data di deposito
13 Mar 2026 14:47
Ultima modifica
13 Mar 2026 14:47
Risorse collegate
Tipologia
Relazione
Identificativo
DOI
questo contributo è un supplemento di
Nome del Progetto
MOST Spoke 13 - Sustainable Mobility Center project
Programma di finanziamento
Next-Generation EU - European Union Next-Generation EU (PIANO NAZIONALE DI RIPRESA E RESILIENZA (PNRR) e MISSIONE 4 COMPONENTE 2, INVESTIMENTO 1.4 e D.D. 1033 17/06/2022
URI

Altri metadati

Statistica sui download

Statistica sui download

Gestione del documento: Visualizza il documento

^